Product Catalogproduct-catalog.htm
ENU
Register Now Forgot Password?

Southwire Product Catalog

 

Our Product Catalog Download requires WinZip file archiving software. Download Winzip

Click here to show/hide usage instructions.
  • Product group offerings are viewed by clicking on the product group description or on the plus symbol next to the folder icon. This will expand and collapse the product group.
  • A product quick view is obtained by hovering over the product item image. This will display product summary information.
  • A complete product page is viewed by clicking on the product item in the expanded list. This will open the catalog page in a PDF file format.
  • To download multiple pages, click on the box in front of the product pages or groups and then click on "Download Products" found at the top and bottom of the product listing. The selected pages will be downloaded as a zipped file to your computer.
  • To narrow product groups, select a filter from the dropdown listbox.
  • AC90 Copper
    • Copper Conductors
    • 14 to 6 AWG, 600 Volts
    • 90°C
    AC90 Copper
  • AC90 ISO-BX Copper
    • Copper Conductors, PVC/Nylon Insulation
    • 14 to 10 AWG, 600 Volts
    • 90°C; -40°C
    AC90 ISO-BX Copper
  • AL-RW90
    • Single Aluminum Conductor.
    • 600 Volts.
    • 90°C Max, -40°C Min.
    • Sizes 6 and Larger Black is Sunlight Resistant.
    AL-RW90
  • Annunciator (Bell) Wire
    • Soft bare copper conductors, thermoplastic insulation.
    • Multiple conductors are twisted.
    • 105°C, 30 Volts.
    Annunciator (Bell) Wire
  • Battery Cable
    • Stranded bare copper with PVC, Rubber, TPR or Cross-link Insulation
    • 85°C, 90°C, 125°C. 50 Volts
    • RoHS
    Battery Cable
  • Blasting Cable
    • Stranded Copper Conductors
    • Neoprene rubber insulation. 60°C
    • RoHS
    Blasting Cable
  • Booster Cable (Twin)
    • Stranded bare copper with PVC, rubber or TPR insulation
    • 90°C, 50 Volts RoHS
    Booster Cable (Twin)
  • Brake Cable
    • Stranded bare or tinned copper conductors.
    • 105°C, 50 Volts.
    Brake Cable
  • CL 1251 / AWM 3173
    • Solid or Stranded Soft Bare or Tinned Copper Conductor. XLPE insulation
    • 125°C Normal Operating Temperature. 600 Volts
    • RoHS
    CL 1251 / AWM 3173
  • CSA SIMpull T90
    • 600 Volts.
    • Copper Conductor.
    • Thermoplastic-Insulated Cable.
    • All Sizes rated TWN75.
    • Gasoline and Oil Resistant.
    CSA SIMpull T90
  • CU - NMWU
    • Underground Feeder and Branch Circuit Cable.
    • 300 Volts. Copper Conductors.
    CU - NMWU
  • FAS
    • Solid or stranded bare copper conductors
    • PVC Insulation 105°C, 300 Volts
    • RoHS
    FAS
  • HDT/GPT/TWP
    • Stranded bare or copper conductors
    • PVC Insulation 85°C, 50 Volts
    • RoHS
    HDT/GPT/TWP
  • HPN
    • Bare copper conductors,
    • 2 or 3 conductors laid parallel.
    • 90°C, 300 Volts.
    HPN
  • HSJO / SJOW
    • Bare copper conductors;
    • 60 or 90°C, 300 Volts.
    HSJO / SJOW
  • Irrigation Cable
    • Solid bare copper; PVC insulation; twisted without fillers;overall PVC jacket.
    • 60°C, 30 Volts.
    Irrigation Cable
  • LVT
    • Solid or stranded soft bare copper conductors.
    • 105°C, 300 Volts.
    LVT
  • PXT / PXWT / XTW
    • Bare stranded copper, laid parallel with PVC insulation.
    • 60°C, 125 Volts - PXT 300 Volts - PXWT -34°C)
    PXT / PXWT / XTW
  • ROMEX® SIMpull® NMD90 Copper
    • Non-metallic Sheathed Cable
    • 300 Volts
    • Copper Conductors
    • SIM Jacket™
    ROMEX® SIMpull® NMD90 Copper
  • RWU
    • Single Aluminum Conductor.
    • 8 and larger AWG, 1000 Volts.
    • 90°C Max, - 40°C Min.
    RWU
  • RWU90 Copper
    • Single Copper Conductors
    • XLPE Insulation
    • 1000 Volts / -40ºC Min, 90ºC Max
    • Sunlight Resistant (In Black)
    RWU90 Copper
  • SIMpull® RW90 Copper
    • Single Copper Conductors
    • XLPE Insulation
    • 600 Volts / -40ºC Min, 90ºC Max
    • Sunlight Resistant
    SIMpull® RW90 Copper
  • SIMpull® RWU90 Copper
    • Single Copper Conductors
    • XLPE Insulation
    • 1000 Volts / -40ºC Min, 90ºC Max
    • Sunlight Resistant
    SIMpull® RWU90 Copper
  • SIMpull® RWU90 ALUMINUM
    • Aluminum Conductors
    • XLPE Insulation
    • 1000 Volts / -40ºC Min, 90ºC Max
    • Sunlight Resistant
    SIMpull® RWU90 ALUMINUM
  • SIMpull® T90 ALUMINUM
    • 600 Volts
    • Aluminum Conductor
    • PVC Insulation
    • All Sizes Rated TWN75
    SIMpull® T90 ALUMINUM
  • Speaker Cable
    • Bare or tinned stranded copper
    • Parallel clear or opaque PVC Insulation.
    • Two Copper Conductors.
    Speaker Cable
  • SPT-1, SPT-2, SPT-3
    • Rated 300 Volts. Rated 105°C
    • Stranded Copper Conductors
    • Thermoplastic Insulation
    • RoHS
    SPT-1, SPT-2, SPT-3
  • SIS
    • Bare or tinned solid or stranded copper
    • 90°C, 600 Volts
    SIS
  • STW
    • Bare copper conductors
    • Thermoplastic insulation
    • 60 or 105°C for ST, -34°C for STW
    • 600 Volts
    STW
  • Submersible Pump Cable
    • Solid or stranded bare copper conductors;
    • individuals PVC insulation;
    • 3 or 4 twisted conductors
    • 600 Volts, -40°C.,
    • Maximum 60°C.
    Submersible Pump Cable
  • SXL/GXL/TXL
    • Stranded bare or tinned copper conductors with cross-linked polyethylene insulation.
    • 125°C, 50 Volts.
    SXL/GXL/TXL
  • TEW/AWM 1015/1019/1020/1230 MTW
    • Solid or stranded bare, tinned, or prefused copper
    • Thermoplastic Insulation, 105°C, 600 Volts
    • RoHS
    TEW/AWM 1015/1019/1020/1230 MTW
  • TR32 AWM Style 1013
    • Solid or stranded tinned copper conductors;
    • PVC insulation.
    • 90°C, 600 Volts.
    TR32 AWM Style 1013
  • TR64 AWM 1007
    • Solid or stranded tinned copper conductors
    • PVC insulation. 90°C, 300 Volts.
    • RoHS
    TR64 AWM 1007
  • Trailer Cable
    • Stranded bare copper conductors with PVC,
    • Rubber or TPR insulation; twisted with overall jacket.
    •  60°C, 90°C, 105°C;-40°C, -65°C.
    • RoHS
    Trailer Cable
  • TW75 Copper
    • Copper Conductors
    • 600 Volts
    • Thermoplastic Sunlight Resistant Insulation
    • All Sizes Rated TW75
    TW75 Copper
  • American Mustang Type SJOOW Yellow
    • American Mustang® 105°C CPE Cord. 300 Volts.
    • Superior Tensile Strength, Elongation and Aging Characteristics.
    • Yellow Jacket. Rated -50°C to 105°C.
    • RoHS Compliant. UL Listed and CSA Certified for Indoor and Outdoor Use.
    • Provides Premium Oil Resistance, Water Resistant and High Flexibility.
    • Excellent Abrasion Resistance.
    American Mustang Type SJOOW Yellow
  • American Mustang Type SOOW Yellow
    • American Mustang® 105°C CPE Cord. 600 Volts.
    • Superior Tensile Strength, Elongation and Aging Characteristics.
    • Yellow Jacket. Rated -50°C to 105°C.
    • RoHS Compliant. UL Listed and CSA Certified for Indoor and Outdoor Use.
    • Provides Premium Oil, Acid, and Water Resistance.
    • High Flexibility and Excellent Abrasion Resistance.
    American Mustang Type SOOW Yellow
  • Hi-Lo Flat Jacketed w Ground
    • Stranded Copper Conductors
    • Rated -50°C to 105°C
    • Dry - 75°C, Wet - 60°C in Oil
    • Water Well Cable
    • 600 Volt
    Hi-Lo Flat Jacketed w Ground
  • Standard UF-B Flat Jacketed Pump Cable (PVC/PVC) w Ground
    • Stranded Copper Conductors
    • Rated -60°C to 150°C
    • 600 Volts
    Standard UF-B Flat Jacketed Pump Cable (PVC/PVC) w Ground
  • Standard Twisted Pump Cable (PVC) w Ground
    • Solid and Stranded Copper Conductors
    • Rated 75°C, 600 Volt
    • Twisted Configuration
    • Water Well Cable
    Standard Twisted Pump Cable (PVC) w Ground
  • Multi-Conductor Sprinkler Wire
    • Solid Bare Copper.
    • PVC Insulation.
    • Overall Poly Jacket.
    • 60°C , 30 Volt.
    • Twisted Without Fillers
    Multi-Conductor Sprinkler Wire
  • RG59 Coax (Copper Conductor)
    • Solid bare or Copper Conductors.
    • PVC Insulation.
    • 95% Copper Braid, 300 Volts
    RG59 Coax (Copper Conductor)
  • RG6 Quad Shield Coax
    • Solid bare Copper Conductors
    • PVC Insulation.
    • 95% Copper Braid, 300 Volts
    RG6 Quad Shield Coax
  • RG6 Coax White Cable
    • Solid bare or Copper Conductors
    • PVC Insulation.
    • 95% Copper Braid, 300 Volts
    RG6 Coax White Cable
  • RG6 Coax Black Cable
    • Solid bare or Copper Conductors
    • PVC Insulation.
    • 95% Copper Braid, 300 Volts
    RG6 Coax Black Cable
  • Canadian Type G-GC and Type G Round
    • 2000 Volts. 90°C(-40°C). Sunlight and Oil Resistant.
    • UL and c(UL) Listed, MSHA Approved, and RoHS Compliant.
    Canadian Type G-GC and Type G Round
  • Type SJTOW - Plastic (PVC)
    • 60°C to -40°C 300 Volts. PVC Jacket
    • Sunlight, Moisture and Oil Resistant
    • UL Listed And CSA Certified
    Type SJTOW - Plastic (PVC)
  • Type STOW - Plastic (PVC)
    • 105°C to -40°C 600 Volts. PVC Jacket
    • Sunlight, Moisture and Oil Resistant
    Type STOW - Plastic (PVC)
  • Viper Non UL/Non CSA SOOW
    • 90°C, 600 Volt Cord
    • Ozone and Flame Resistant
    • Black Jacket. Rated -40°C to 90°C
    • RoHS Compliant. Indoor and Outdoor Use
    • Provides Moisture and Oil Resistance
    Viper Non UL/Non CSA SOOW
  • In-wall Speaker Wire
    • Annealed Bare Copper
    • PVC Insulation
    • Two Copper Conductors
    In-wall Speaker Wire
  • Security/Fire Alarm Cable (CMR) Unshielded
    • Solid Bare Copper
    • Flame Retardant PVC Insulation
    • 105°C , 300 Volt
    Security/Fire Alarm Cable (CMR) Unshielded
  • Security/Fire Alarm Cable (CMR) Shielded
    • Solid Bare Copper
    • Flame Retardant PVC Insulation
    • 105°C , 300 Volt
    Security/Fire Alarm Cable (CMR) Shielded
  • SVT Cord
    • Stranded Copper Conductors.
    • 300 Volts; 60 or 105°C.
    • PVC Jacket
    SVT Cord
  • Category 6 Riser Cable
    • Solid Annealed Copper Conductors
    • Thermoplastic Insulation
    Category 6 Riser Cable
  • Category 6 Plenum Cable
    • CMP FR low smoke PVC Jacket
    • Solid Annealed Copper Conductors
    • Thermoplastic Insulation
    Category 6 Plenum Cable
  • Category 5e Riser Cable
    • Solid Annealed Copper Conductors
    • Thermoplastic Insulation
    Category 5e Riser Cable
  • Category 5e Plenum Cable
    • CMP FR low smoke PVC Jacket
    • Solid Annealed Copper Conductors
    • Thermoplastic Insulation
    Category 5e Plenum Cable
  • Category 5e Indoor/Outdoor Cable
    • Solid Annealed Copper Conductors
    • Thermoplastic Insulation
    Category 5e Indoor/Outdoor Cable
  • Category 3 Riser Cable
    • Solid Annealed Copper Conductors.
    • Thermoplastic Insulation
    Category 3 Riser Cable
  • Shielded SOOW Cable
    • 90°C, 600 Volts.Flexible Stranding. Water Resistant 60°C.
    • Black Jacket. Rated -40°C to 90°C. RoHS Compliant.
    • UL Listed and CSA Certified for Indoor and Outdoor Use.
    • 18 AWG - 10 AWG - Multi-conductor Shielded
    Shielded SOOW Cable
  • Low Energy Cable/Single Conductor UF
    • Low-Energy Circuit Cable
    • Type UF Single Conductor Cable is 600 Volts
    • Low Energy Circuit Cable is 150 volt.
    • Solid Bare copper, 60°C PVC Insulation
    Low Energy Cable/Single Conductor UF
  • Wire / Tracer Wire
    • Bare Copper Conductor
    • Polyethylene Insulation
    • -25°C to 75°C, 600 Volt

    Wire / Tracer Wire
  • Standard Flat Jacketed Pump Cable (PVC/PVC) w/o Ground
    • Stranded Copper Conductors
    • Rated 75°C, 600 Volt
    • Water Well Cable
    Standard Flat Jacketed Pump Cable (PVC/PVC) w/o Ground
  • Temporary Jumper Cable
    • Single Conductor
    • 4 AWG - 500 kcmil
    • 90°C Damp or Dry Locations
    • 5/15kV EPR Insulation, Non-Shielded
    Temporary Jumper Cable
  • Red Welding Cable
    • 600 Volts. Rated for -55°C to 105°C. Sizes 6 AWG - 500 MCM.
    • Good Flexibility. Oil Resistant.
    • Resists Compression, Cuts and Abrasion.
    • Red EPDM Jacket, RoHS Compliant.
    Red Welding Cable
  • Viper ® Non UL/Non CSA SOW
    • 90°C, 600 Volt Cord
    • Ozone and Flame Resistant
    • Black CPE Jacket. Rated -40°C to 90°C
    • RoHS Compliant. Indoor and Outdoor Use
    • Provides Moisture and Oil Resistance
    Viper ® Non UL/Non CSA SOW
  • 2KV Diesel Locomotive Cable
    • Diesel Locomotive Cable (DLO) Rated 2000 Volts. 90°C. CT Rated
    • UL Listed as Type RHH/RHW-2
    • CSA Certified as RW90. RoHS Compliant
    2KV Diesel Locomotive Cable
  • QuantumTPE SJEOOW Black
    • Southwire's Quantum® SJEOOW 105°C TPE Cord. 300 Volts.
    • Black Jacket. Rated -50°C to 105°C. RoHS Compliant
    • Rated as Hard-Usage Service Cord.
    • Sizes 18 AWG - 10 AWG CSA Certified as Type SJTOOW (TPE) and meets CSA FT-2.
    • Listed for Outdoor Use. Provides Premium Oil Resistance, Water Resistance and Flexibility.
    QuantumTPE SJEOOW Black
  • QuantumTPE SEOOW Black
    • Southwire's Quantum® SEOOW 105°C TPE Cord. 600 Volts.
    • Black Jacket. Rated -50°C to 105°C. RoHS Compliant
    • Rated as Extra Hard-Usage Service Cord.
    • Sizes 18 AWG - 10 AWG CSA Certified as Type STOOW (TPE) and meet CSA FT-2.
    • Sizes 8-2 AWG are non-UL and non-CSA Listed.
    • Listed for Outdoor Use. Provides Premium Oil Resistance, Water Resistance and Flexibility.
    QuantumTPE SEOOW Black
  • QuantumTPE SJEOOW Yellow
    • Quantum™ 105°C TPE Cord. 300 Volts. Flexible Copper Conductors.
    • Extra Flexible Thermoplastic-Elastomer (TPE) Insulation and Jacket.
    • Yellow Jacket.  Rated -50°C to 105°C. RoHS Compliant.
    • Rated as Hard-Usage Service Cord.
    • CSA Approved as Type SJTOOW (TPE) at -50°C to 105°C and meets CSA FT-2.
    • Listed for Outdoor Use. Provides Premium Oil Resistance, Water Resistance and Flexibility.
    QuantumTPE SJEOOW Yellow
  • QuantumTPE SEOOW Yellow
    • Quantum™ 105°C TPE Cord. 600 Volts. Flexible Copper Conductors.
    • Extra Flexible Thermoplastic-Elastomer (TPE) Insulation and Jacket.
    • Yellow Jacket. Rated -50°C to 105°C. RoHS Compliant.
    • Rated as Extra Hard-Usage Service Cord.
    • Sizes 18 AWG - 10 AWG CSA Certified as Type STOOW (TPE) and meet CSA FT-2.
    • Sizes 8-2 AWG are non-UL and non-CSA Listed.
    • Approved for Outdoor Use. Provides Premium Oil Resistant, Water Resistace and Flexibility.
    QuantumTPE SEOOW Yellow
  • Viper Rubber Type SJOOW Black
    • VIPER® 90°C Cord. 300 Volts
    • Good Tensile Strength, Elongation and Aging Characteristics
    • Black Jacket. Rated -40°C to 90°C
    • RoHS Compliant. UL Listed and CSA Certified for Indoor and Outdoor Use
    • Provides Premium Oil Resistance, Water Resistant and High Flexibility
    • Excellent Abrasion Resistance
    • NEC, Rated Hard Usage.
    Viper Rubber Type SJOOW Black
  • Viper Rubber Type SOOW Black
    • VIPER® 90°C CPE Cord. 600 Volts
    • Flexible Stranding. Flame and Ozone Resistant
    • Black Jacket. Rated -40°C to 90°C
    • RoHS Compliant. UL Listed and CSA Certified for Indoor and Outdoor Use
    • Provides Premium Oil Resistance, Water Resistant and High Flexibility
    • Excellent Abrasion Resistance
    • NEC, Rated Extra-Hard Usage
    Viper Rubber Type SOOW Black
  • Viper Rubber Type SJOOW Yellow
    • VIPER® 90°C CPE Cord. 300 Volts
    • Good Tensile Strength, Elongation and Aging Characteristics
    • Yellow Jacket. Rated -40°C to 90°C
    • RoHS Compliant. UL Listed and CSA Certified for Indoor and Outdoor Use
    • Provides Premium Oil Resistance, Water Resistant and High Flexibility
    • Excellent Abrasion Resistance
    • NEC, Rated Hard-Usage
    Viper Rubber Type SJOOW Yellow
  • Viper Rubber Type SOOW Yellow
    • VIPER® 90°C CPE Cord. 600 Volts
    • Flexible Stranding. Flame and Ozone Resistant
    • Yellow Jacket. Rated -40°C to 90°C
    • RoHS Compliant. UL Listed and CSA Certified for Indoor and Outdoor Use
    • Provides Premium Oil Resistance, Water Resistant and High Flexibility
    • Excellent Abrasion Resistance
    • NEC, Rated Hard-Usage
    Viper Rubber Type SOOW Yellow
  • Viper Rubber Type Multi-Conductor Type SOOW Control
    • Viper™ 90°C CPE Cord. 600 Volts.
    • Flexible Stranding. Flame and Ozone Resistant.
    • Black Jacket. Rated -40°C to 90°C.
    • RoHS Compliant. UL Listed and CSA Certified for Indoor and Outdoor Use.
    • Provides Premium Oil Resistance, Water Resistant and High Flexibility.
    • Excellent Abrasion Resistance.
    Viper Rubber Type Multi-Conductor Type SOOW Control
  • Type SJTOOW - Plastic (PVC)
    • 105°C PVC Cord. 300 Volts. Flexible Copper Conductors.
    • Flexible PVC  Insulation and Jacket.
    • Grey or Yellow Jacket.  Rated -34°C to 105°C. Rated as Hard-Usage Service Cord.
    • Flame Retardant and Meets UL and CSA FT2 Flame Tests.
    • Approved for Outdoor Use. Provides Premium Oil Resistance, Water Resistant, and Flexibility.
    Type SJTOOW - Plastic (PVC)
  • Type STOOW - Plastic (PVC)
    • 105°C PVC Cord. 600 Volts. Flexible Copper Conductors.
    • Flexible PVC Insulation and Jacket.
    • Grey or Yellow Jacket. Rated -34°C to 105°C. Rated as Extra Hard-Usage Service Cord.
    • Flame Retardant and Meets UL and CSA FT2 Flame Tests.
    • Approved for Outdoor Use. Provides Premium Oil Resistance, Water Resistant, and Flexibility.
    Type STOOW - Plastic (PVC)
  • Bus Drop Cable
    • Resistant to Oils, Lubricants, Acids, Alkalies, Ozone, Water and Abrasion.
    • One Uninsulated Ground Conductor per Interstice. Used in Wet or Dry Locations. 600 Volt.
    • UL Listed. OSHA Acceptable. RoHSCompliant. -20°C to 75°C(14-8 awg), 60°C (6-2 awg).
    Bus Drop Cable
  • Black non-UL Welding Cable
    • 600 Volts. Rated for -55°C to 105°C. Sizes 6 AWG - 500 MCM.
    • Good Flexibility. Oil Resistant.
    • Resists Compression, Cuts and Abrasion.
    • Black EPDM Jacket, RoHS Compliant.
    Black non-UL Welding Cable
  • American Mustang ® Orange Welding Cable
    • Premium Grade Orange CPE Jacket. . 
    • Superior Flexibility, Flame Retardant, Oil and Solvents Resistant.
    • Weather and Ozone Resistant.
    • 105°C to -55°C 600 Volt.
    American Mustang ® Orange Welding Cable
  • Type W Portable Power Cable
    • Type W Industrial Grade Single and Multiconductor Portable Round Power Cable
    • 2000 Volt. 90°C (-40°C). Oil and Sunlight Resistant.
    • Single Conductors Listed as Type RHH/RHW-2.
    • UL and c(UL) Listed. CSA Certified. MSHA Approved. RoHS Compliant.
    Type W Portable Power Cable
  • Type G and Type G-GC Round
    • 2000 Volts. 90°C(-40°C). Sunlight and Oil Resistant.
    • UL and c(UL) Listed, MSHA Approved, and RoHS Compliant.
    Type G and Type G-GC Round
  • Type SC Entertainment Cable
    • Type SC Entertainment Cable. 600 Volts. Extra Flexible Copper Conductors.
    • Water and Sunlight Resistant. Designed to Withstand Severe Environmental Conditions. 
    • 105°C to -40°C. Listed for Indoor or Outdoor Use. Flame Retardant.
    • Provides Flexibility, Resistance to Oil, Solvents, Ozone, Aging, and Abrasion.
    Type SC Entertainment Cable
  • MTW/TEW or AWM-I A
    • 600 Volts. Copper Conductor. Polyvinyl Chloride (PVC) Insulation.
    • Heat, Moisture, and Oil Resistant. AWG Sizes 18 through 2 rated
    • MTW/TEW or AWM. All sizes meet UL VW-1 and Oil Resistant I.
    • AWG sizes 14 through 2 meet oil resistant II and THW-2 and AWG sizes 18 and 16 meet TFF.
    • All sizes meet CSA FT-1 and Oil Resistant I. RoHS
    MTW/TEW or AWM-I A
  • Low - Voltage Landscape Lighting Cable
    • Rated 150 Volts. Rated -20°C to 60°C.
    • Listed for Outdoor Use (Sunlight Resistant).
    • Suitable for Direct Burial.
    • Stranded Copper Conductors.
    • Black PVC Insulation/Jacket.
    Low - Voltage Landscape Lighting Cable
  • Coaxial Cable
    • 75 OHM RG 59/U WITH 20 AWG WITH 95% BRAID. 
    • RG 6/U WITH 18 AWG WITH 95% BRAID.
    • QUAD-SHIELD RG 6/U WITH 18 AWG WITH 95% BRAID.
    Coaxial Cable
  • Thermostat Wire
    • Rated 150 Volts.
    • Sunlight-Resistant -20°C to 60°C.
    • 18 and 20 Gauge Copper Conductors.
    • Sunlight Resistant
    Thermostat Wire
  • Trailer Cable
    • Stranded bare copper conductors with PVC,
    • Rubber or TPR insulation;
    • twisted with overall jacket.
    • 60°C, 90°C, 105°C;-40°C, -65°C.
    Trailer Cable
  • Speaker Cable
    • Bare or tinned stranded copper
    • Parallel clear or opaque PVC insulation
    • Two copper conductors
    Speaker Cable
  • Booster Cable
    • Stranded bare copper with PVC and TPE Insulation
    • 85°C and 105°C, 50 Volts
    Booster Cable
  • Brake Cable
    • Stranded Bare or Tinned Copper Conductors.
    • 85°C and 105°C, 50 Volts.
    Brake Cable
  • SGT / SGR / SGX Battery Cable
    • Stranded bare copper with PVC, Rubber, TPR or Cross-Link Insulation.
    • 85°C (SGT), 90°C (SGR), 125°C (SGX). 60 Volts.
    SGT / SGR / SGX Battery Cable
  • Bell Wire
    • Soft bare copper conductors, thermoplastic insulation.
    • Multiple conductors are twisted.
    • 105°C, 30 Volts.
    Bell Wire
  • Irrigation Cable
    • Solid bare copper; PVC insulation;
    • twisted without fillers; overall PVC jacket.
    • 60°C, 30 Volts.
    Irrigation Cable
  • Submersible Pump Cable
    • Solid or stranded bare copper condutors;
    • individuals PVC insulation;
    • 3 or 4 twisted conductors
    • 600 Volts, -40°C., Maximum 60°C.
    Submersible Pump Cable
  • SPT
    • Rated 300 Volts. Rated 105°C or 60°C.
    • Stranded Copper Conductors.
    • Color Coded PVC Insulation/Jacket.
    SPT
  • Primary Wire GPT
    • Stranded bare or copper conductors
    • Premium PVC Insulation.
    • 85°C, 60 Volts.
    Primary Wire GPT
  • GXL
    • Stranded bare or copper conductors
    • PVC insulation
    • 125°C, 60 Volts
    GXL
  • Primary Wire SXL
    • Stranded bare or copper conductors
    • PVC Insulation.
    • 125°C, 60 Volts.
    Primary Wire SXL
  • TelcoSafe ™
    • 600 Volts, Copper Conductor, 90°C Dry, 75°C Wet
    • Central Office Power Wire and Cable
    • Flexible Central Office Power Wire and Cable
    • CSA approved, Non-Halogen Insulation
    • 8 AWG thru 750 KCMIL - Single Conductor
    TelcoSafe ™
  • TelcoFlex ® II
    • 600 Volts, Copper Conductor  
    • Class l Flexible Strand Without Braid
    • CSA Approved, Non-Halogen  Insulation
    • 8 AWG thru 750 KCMIL - Single Conductor
    TelcoFlex ® II
  • TelcoFlex ® III
    • 600 Volts, Copper Conductor
    • Central Office / Telecom Power Cable
    • Class B Strand With Braid
    • CSA approved, Non-Halogen Insulation
    • 14 AWG - 750 KCMIL - Single Conductor
    TelcoFlex ® III
  • TelcoFlex ® IV
    • 600 Volts, Copper Conductor  
    • Class l Flexible Strand With Braid
    • CSA approved, Non-Halogen Insulation
    • 8 AWG - 750 KCMIL - Single Conductor
    TelcoFlex ® IV
  • AAAC-6201
    • All Aluminum Alloy Conductor.
    • Bare.
    AAAC-6201
  • AAC
    • All Aluminum Conductor.
    • Bare.
    AAC
  • ACSR
    • Aluminum Conductor.
    • Steel Reinforced 1.
    • Bare.
    ACSR
  • ACSR/AW
    • Aluminum Conductor.
    • Aluminum-Clad Steel Reinforced.
    • Bare.
    ACSR/AW
  • ACAR
    • Aluminum Conductor.
    • Aluminum Alloy Reinforced.
    • Bare.
    ACAR
  • ACSR/TW
    • Aluminum Conductor.
    • Steel Reinforced.
    • Trapezoidal Shaped Aluminum Strands.
    • Bare.
    ACSR/TW
  • AAC/TW
    • All Aluminum Conductor.
    • Trapezoidal Shaped Conductors.
    • Bare.
    AAC/TW
  • Motion-Resistant Conductor
    • ACSR Motion-Resistant Conductor.
    • Bare Aluminum Conductor, Steel Reinforced.
    Motion-Resistant Conductor
  • VR2 Cable
    • Vibration-Resistant.
    • Bare Aluminum Cable.
    • Available in AAC and ACSR Constructions.
    VR2 Cable
  • ACSS
    • Aluminum Conductor, Steel Supported.
    ACSS
  • ACSS/AW
    • Aluminum Conductor.
    • Aluminum-Clad Steel Supported.
    ACSS/AW
  • ACSS/TW
    • Aluminum Conductor, Steel Supported.
    • Trapezoidal Shaped Aluminum Strands.
    • Bare.
    ACSS/TW
  • Armor Wire/Binder Tape
    • Aluminum Armor Wire and Binder Tape.
    • Rectangular Soft 1350 Aluminum Alloy.
    Armor Wire/Binder Tape
  • Tie & Ground Wire
    • Aluminum Tie and Ground Wire.
    • Solid Soft 1350 Aluminum Alloy.
    Tie & Ground Wire
  • Covered Line Wire
    • Aluminum Conductor.
    • Polyethylene or Crosslinked Polyethylene Covering.
    Covered Line Wire
  • Single Conductor 600V
    • Aluminum Conductor.
    • Cross-linked Polyethylene (XLP) Insulation.
    Single Conductor 600V
  • Duplex 600V Secondary UD
    • Aluminum Conductors.
    • Cross-linked Polyethylene (XLP) Insulation.
    Duplex 600V Secondary UD
  • Triplex 600V Secondary UD
    • Aluminum Conductors.
    • Cross-linked Polyethylene (XLP) Insulation.
    Triplex 600V Secondary UD
  • Quadruplex 600v
    Quadruplex 600v
  • HI-SCORE Single Conductor 600V
    • Aluminum Conductor.
    • Ruggedized XLP Insulation.
    • Provides Superior Mechanical Protection.
    HI-SCORE Single Conductor 600V
  • HI-SCORE Duplex 600V
    • Aluminum Conductors.
    • Ruggedized XLP Insulation.
    • Provides Superior Mechanical Protection.
    HI-SCORE Duplex 600V
  • HI-SCORE Triplex 600V
    • Aluminum Conductor.
    • Ruggedized XLP Insulation.
    • Provides Superior Mechanical Protection.
    HI-SCORE Triplex 600V
  • HI-SCORE Quadruplex 600V
    • Aluminum Conductors.
    • Ruggedized XLP Insulation.
    • Provides Superior Mechanical Protection.
    HI-SCORE Quadruplex 600V
  • SureSeal ® Duplex 600V
    • Unique Cable Design with an Encapsulated Flowable Visco-Elastic Sealant.
    • Sealant Provides Extended Cable Life After Minor Mechanical Cable Damage.
    • Sealant also Provides Extended Cable Life when Pinholes are Caused by Voltage Surges.
    SureSeal ® Duplex 600V
  • SureSeal ® Triplex 600V
    • Unique Cable Design with an Encapsulated Flowable Visco-Elastic Sealant.
    • Sealant Provides Extended Cable Life After Minor Mechanical Cable Damage.
    • Sealant also Provides Extended Cable Life when Pinholes are Caused by Voltage Surges.
    SureSeal ® Triplex 600V
  • SureSeal ® Quadruplex 600V
    • Unique Cable Design with an Encapsulated Flowable Visco-Elastic Sealant.
    • Sealant Provides Extended Cable Life After Minor Mechanical Cable Damage.
    • Sealant also provides Extended Cable Life when Pinholes are Caused by Voltage Surges.
    SureSeal ® Quadruplex 600V
  • SureSeal ® Single Conductor 600V
    • Unique Cable Design with an Encapsulated Flowable Visco-Elastic Sealant.
    • Sealant Provides Extended Cable Life After Minor Mechanical Cable Damage.
    • Sealant also Provides Extended Cable Life when Pinholes are Caused by Voltage Surges.
    SureSeal ® Single Conductor 600V
  • 8000 Series AL Triplex 600V
    • TRIPLE E Aluminum Alloy (AA-8176) Conductors.
    • Cross-linked Polyethylene (XLP) Insulation.
    8000 Series AL Triplex 600V
  • PowerGlide Triplex 600V
    • Aluminum conductor
    • Cross-linked polyethylene (XLP) insulation
    • Easy to pull or push
    PowerGlide Triplex 600V
  • PowerGlide Quadruplex 600V
    • Aluminum Conductor
    • Cross-linked Polyethylene (XLP) Insulation
    • Easy to Pull or Push
    PowerGlide Quadruplex 600V
  • PowerGlide HI-SCORE Triplex 600V
    • Aluminum Conductor.
    • Ruggedized Cross-linked Polyethylene (XLP) Insulation.
    • Provides Superior Mechanical Protection.
    • Easy to Pull or Push.
    PowerGlide HI-SCORE Triplex 600V
  • PowerGlide HI-SCORE Quadruplex 600V
    • Aluminum Conductor.
    • Ruggedized Cross-linked Polyethylene (XLP) Insulation.
    • Provides Superior Mechanical Protection.
    • Easy to Pull or Push.
    PowerGlide HI-SCORE Quadruplex 600V
  • 15kV HI-DRI UD
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    15kV HI-DRI UD
  • 25kV HI-DRI UD
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    25kV HI-DRI UD
  • 28kV HI-DRI UD
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    28kV HI-DRI UD
  • 35kV HI-DRI UD
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    35kV HI-DRI UD
  • 15kV HI-DRI Jacketed
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    • Polyethylene Jacket.
    15kV HI-DRI Jacketed
  • 25kV HI-DRI Jacketed
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    • Polyethylene Jacket.
    25kV HI-DRI Jacketed
  • 28 kV HI-DRI Jacketed
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    • Polyethylene Jacket.
    28 kV HI-DRI Jacketed
  • 35 kV HI-DRI Jacketed
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    • Polyethylene Jacket.
    35 kV HI-DRI Jacketed
  • 15kV-35kV LCT Shielded
    • Aluminum or Copper Conductors.
    • Tree-Retardant Cross-linked Polyethylene (TRXLP) Insulation.
    • Copper Longitudinal Corrugated Tape (LCT) Shield.
    15kV-35kV LCT Shielded
  • 15 kV PowerGlide MV Primary UD Cable
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    • Engineered PowerGlide™ Polyethylene Jacket.
    15 kV PowerGlide MV Primary UD Cable
  • 25 kV PowerGlide MV Primary UD Cable
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    • Engineered PowerGlide™ Polyethylene Jacket.
    25 kV PowerGlide MV Primary UD Cable
  • 28 kV PowerGlide MV Primary UD Cable
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    • Engineered PowerGlide™ Polyethylene Jacket.
    28 kV PowerGlide MV Primary UD Cable
  • 35 kV PowerGlide MV Primary UD Cable
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    • Engineered PowerGlide™ Polyethylene Jacket.
    35 kV PowerGlide MV Primary UD Cable
  • LCT Shielded PowerGlide MV Primary UD Cable
    • Aluminum or Copper Conductors.
    • TRXLP Insulation.
    • Copper Longitudinal Corrugated Tape Shield (LCT).
    • Engineered PowerGlide™ Polyethylene Jacket.
    LCT Shielded PowerGlide MV Primary UD Cable
  • HV Cable System Options
    • Feasibility studies and conceptual engineering
    • Detailed underground system design
    • Pulling calculations
    HV Cable System Options
  • 161kV
    • Compressed Round or Compacted Segmental Conductor
    • Corrugated Metallic Sheath or Cu Laminate Sheath
    • True Triple Extrusion
    • Super Clean XLPE Insulation
    161kV
  • 115kV
    • Compressed Round or Compacted Segnental Conductor
    • Corrugated Metallic Sheath or Cu Laminate Sheath
    • True Triple Extrusion
    • Super Clean XLPE Insulation
    • Insulation thickness 550 mils-800 mils
    115kV
  • 69kV
    • Compressed Round or Compacted Segmental Conductor
    • Corrugated Metallic Sheath or Cu Laminate Sheath
    • True Triple Extrusion
    • Super Clean XLPE Insulation
    • Insulation thickness 450 mild-650 mils
    69kV
  • 138kV
    • Compressed Round or Compacted Segmental Conductor
    • Corrugated Metallic Sheath or Cu Laminate Sheath
    • True Triple Extrusion
    • Super Clean XLPE Insulation
    • Insulation thickness 650 mils-850 mils
    138kV
  • 230kV
    • Compressed Round or Compacted Segmental Conductor
    • Corrugated Metallic Sheath or Cu Laminate Sheath
    • True Triple Extrusion
    • Super Clean XLPE Insulation
    • Insulation thickness 850 mils-900 mils
    230kV
  • Outdoor Porcelain Termination
    • Premolded Stress Control System
    • Silicon Fluid Filled
    • Epoxy Standoff Insulators
    • Porcelain Insulator
    • Available from 69kV-230kV
    Outdoor Porcelain Termination
  • Dry Type Plug In Termination
    • Silicone Rubber Stress Cone
    • Plugs into Switchgear Connector
    • Mechanical Screw Top Connector
    • Available up to 145kV
    Dry Type Plug In Termination
  • Epoxy Insulator Termination
    • Silicone Rubber Stress Cone
    • Plugs into Swithgear Connector
    • Mechanical Screw Top Connector
    • Available up to 145kV
    Epoxy Insulator Termination
  • Joint
    • Premolded Joint
    • 3 Piece Design
    • Screw top or Compressed Conductor Connector
    • Compact Dimensions
    • Available from 69kV-230kV
    Joint
  • FEV-V Outdoor Termination with Composite Insulator
    • Premolded Stress Control System
    • Silicon Fluid Filled
    • Epoxy Standoff Insulators
    • Composite Insulator
    • Available from 69kV-230kV
    FEV-V Outdoor Termination with Composite Insulator
  • Aluminum Cable Clamps
    Aluminum Cable Clamps
  • Bonding Cable
    Bonding Cable
  • Link Boxes
    • Stainless steel box
    • Moisture tight and water impervious options available for both outdoor and vault applications
    • Suitable for all voltage classes
    • Zinc oxide sheath voltage limiters
    • Single point, cross-bonding, and direct grounding versions available, with or without removable links
    • Accommodates single core or concentric bonding cables of different diameters
    • 1 phase and 3 phase boxes
    • Different mechanical protection levels up to IP68
    • Short circuit current up to 40 kA for 1 sec
    Link Boxes
  • 5kV Covered Aerial MV Cable - Tree Wire
    • B-230 Aluminum, 1350-H19 Wire for Electrical Purposes.
    • B-231 Concentric-Lay-Stranded Aluminum 1350 Conductors.
    • B-232 Concentric-Lay-Stranded, Aluminum Conductors, Coated Steel Reinforced (ACSR).
    • B-498 Zinc-Coated (Galvanized) Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
    • B-399 Standard Specification for Concentric-Lay-Stranded, Aluminum Alloy 6201-T81 Conductors.
    5kV Covered Aerial MV Cable - Tree Wire
  • Multi-Layer 15kV - 46kV Spacer Cable
    • Aluminum Conductor.
    • Track-Resistant HD Polyethylene or Track Resistant Crosslinked polyethylene Covering.
    Multi-Layer 15kV - 46kV Spacer Cable
  • Multi-Layer 15kV - 35kV Tree Wire
    • Aluminum Conductor.
    • Track-Resistant HD Polyethylene or Track-Resistant Crosslinked Polyethylene Covering.
    Multi-Layer 15kV - 35kV Tree Wire
  • Messenger
    • High Strength to Weight
    • Equivalent Conductivity to Bare Aluminum
    • Protects covered conductors from physical damage
    • Superior corrosion resistance
    Messenger
  • 15 kV Polymer Insulator
    • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
    • Insulator is molded from grey track resistant polyethylene compound
    • UV resistant
    • Lightweight and shatter resistant
    15 kV Polymer Insulator
  • 15kV Polymer Vise-Top Insulator
    • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
    • Insulator is molded from grey track resistant polyethylene compound
    • UV resistant
    • Lightweight and shatter resistant
    • Special clamp with torque colibrated holding bolts
    • Available for both covered and bare conductors
    15kV Polymer Vise-Top Insulator
  • 35kV Polymer Insulator
    • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
    • Insulator is molded from a track resistant polyethylene compound
    • UV resistant
    • Lightweight and shatter resistant
    35kV Polymer Insulator
  • 35kV Polymer Vise-Top Insulator
    • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
    • Insulator is molded from grey track resistant polyethylene compound
    • UV resistant
    • Lightweight and shatter resistant
    • Special clamp with torque calibrated holding bolts
    • Can be easily used in hot stick applications
    • Nylon inserts for covered conductors
    • Metallic inserts for bare conductors
    35kV Polymer Vise-Top Insulator
  • Tie Wire
    • Compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
    • Compatible with Southwire's and other manufacturers' SCS accessories
    • UV resistant
    • Flexible and easy to install
    • Track resistant
    Tie Wire
  • Torque Bolt
    • Special reduced cross section that is calibrated to provide the optimum clamping force for this cable with break-off eye
    • UV resistant
    • Lightweight and shatter resistant
    Torque Bolt
  • Vise-Top Stringing Tool
    • Stringing Tool molded from a polyurethane compound
    • Lightweight and shatter resistant
    • Designed to be operated either by hot stick or by hand
    • Designed for low friction by hot stick or by hand
    • Designed for low friction with both pulling rope and covered conductors.
    • Easy to install and remove
    Vise-Top Stringing Tool
  • Ring Ties
    • Compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
    • Ring Ties are molded from a long life track resistant silicone compound
    • UV resistant
    Ring Ties
  • 46kV RatchetLock Spacer
    • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
    • RatchetLock Spacer is molded from a track-resistant high-density polyethylene compound
    • UV resistant
    • Lightweight and shatter resistant
    • Does not require seperate ring ties
    46kV RatchetLock Spacer
  • 35kV Spacer
    • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
    • 35kV Spacer is molded from grey high-density track-resistant polyethylene compound
    • UV resistant
    • Lightweight and shatter resistant
    35kV Spacer
  • 15kV Three Phase Vertical Spacer
    • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
    • 15kV 3-Phase Vertical Spacer is molded from grey track-resistant high-density polyethylene compound
    • UV resistant
    • Lightweight and shatter resistant
    15kV Three Phase Vertical Spacer
  • 15kV Spacer
    • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
    • 15kV Spacer is molded from grey high-density track resistant polyethylene compound
    • UV resistant
    • Lightweight and shatter resistant
    • Can be used on any 5kV - 15kV Covered Aerial MV system
    15kV Spacer
  • 15kV Single Phase Spacer
    • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
    • 15kV Single Phase Spacer is molded from grey track-resistant polyethylene compound
    • UV resistant
    • Lightweight and shatter resistant
    15kV Single Phase Spacer
  • 15kV RatchetLock Spacer
    • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
    • RatchetLock Spacer is molded from grey track-resistant high-density polyethylene compound
    • UV resistant
    • Lightweight and shatter resistant
    • Does not require seperate ring ties
    15kV RatchetLock Spacer
    • Manufactured from high-strength structural steel
    • Corrosion resistant
    • Maintains proper Covered Aerial MV cable orientation
    • Drilled for use on standard utility poles
    "C" Bracket
    • Manufactured from high-strength structural steel
    • Corrosion resistant
    • Maintains proper Covered Aerial MV cable orientation
    • Drilled for use on standard utility poles
    "E" Bracket
  • Anti-sway Bracket
    • Designs that allow flexibility in attachment to the pole
    • Compatible and interchangeable with other manufacturers accessories
    • Lightweight and shatter resistant
    • UV resistant
    Anti-sway Bracket
  • Dead-end Bracket
    • Manufactured from high strength structural steel
    • Corrosion resistant
    • Allows for compact configuration for dead-ending
    • Drilled for use on standard utility poles
    • Uses Standard "C" Bracket and Angle Cross Arm increasing part interchangeability
    Dead-end Bracket
  • Double Insulator Plate
    • Manufactured by casting from ductile iron
    • Corrosion resistant
    • Drilled for 10" insulator spacing
    Double Insulator Plate
  • Messenger Angle Clamps
    • Excellent corrosion resistance
    • Designed to hold up to 14,000 pounds
    • For line angles of up yo 60 degrees
    Messenger Angle Clamps
  • Messenger Clamp
    • Corrosion resistant
    • Designed to allow roll-by installation of Covered Aerial MV cables
    • Will support a wide range of messenger sizes
    Messenger Clamp
  • Tangent
    • Ductile iron construction for higher strength
    • Low profile design without loss of strength
    • Corrosion resistant
    Tangent "L" Bracket
  • Tangent
    • Corrosion resistant
    • Optimally shaped to provide high strength and to maintain optimum cable configuration
    • Enable conductor support at structure and use of anti-sway bracket
    • Attachment hardware provided
    Tangent "L" Bracket Stirrup
  • Transformer Tap Bracket
    • manufactured from-strength structural stell channel
    • Excellent corrosion resistance
    • Provides increased Covered Aerial MV cable spacing to facilitate operations
    Transformer Tap Bracket
  • U-Bolt
    • Excellent corrosion resistance
    • 1 1/2" hole spacing
    • 4 1/2" total length
    • Includes mounting nuts and washers
    U-Bolt
  • Vertical Tap Bracket
    • Manufactured from high-strength structural steel
    • Corrosion resistant
    • Drilled for use on standard utility poles
    • Allows for tap circuit connections with adequate room for connections in minimal space
    Vertical Tap Bracket
  • Messenger Dead-ends
    • Longitudinal Holding Strength equal to messenger UTS
    • Uniform radial pressure exerted on the messenger
    • Designed for specific messenger sizes
    • Color coded for ease of selection in field
    Messenger Dead-ends
  • Clevises
    • Excellent corrosion resistance
    Clevises
  • Coated Conductor Dead-ends
    • Longitudinal hold strength for spacer cable applications
    • Uniform radial pressure exerted on the conductor cover
    • Designed for specific conductor diameters
    • Color coded for ease of selection in field
    • Coating is compatible with covered conductors
    Coated Conductor Dead-ends
  • Dielectric Wedge Dead-end
    • Ease of installation
    • Designed for specific conductor diameters
    • Compatible with all manufacturers’ Covered Aerial MV cable
    Dielectric Wedge Dead-end
  • Insulator Pins
    • Manufactured from cold rolled steel
    • Corrosion resistant
    • Compatible and interchangeable with Pin Insulators from all manufacturers
    Insulator Pins
  • Messenger Splices
    • Longitudinal holding strength equal to messenger
    • Uniform radial pressure exerted on the messenger
    • Designed for specific messenger sizes
    • Color coded for ease of selection in field
    Messenger Splices
  • Pole Extensions - 30
    • Manufactured from high-strength structural steel
    • Corrosion resistant
    • Drilled for use on standard utility poles
    • Used to provide additional pole height to allow for the installation of additional Covered Aerial MV cable circuit to the pole line
    Pole Extensions - 30"
  • Pole Extensions - >30
    • Manufactured from high-strength structural steel
    • Superior corrosion resistance
    • Pre-drilled for use on standard utility poles
    • Used to provide additional pole height to allow for the installation of Covered Aerial MV circuits to existing pole lines
    • The high-strength variations are available where double circuit or higher circuit loadings need to be acommodated. Two straight structural steel channel sections are used (not shown)
    Pole Extensions - >30"
  • Polymer Dead-end Insulators
    • High strength-to-weight ratio
    • Excellent hydrophobicity
    • Lightweight and shatter resistant
    • Low profile for compact construction
    Polymer Dead-end Insulators
  • Protective Guards
    • UV and track-resistant
    • Lightweight and shatter resistant
    • Incorporates tie hole for securing to messenger
    • Designed for specific messenger sizes
    • Can be cut to lenth in the field
    • Available in black or grey
    Protective Guards
  • Stripping Tool
    • Ease of use
    • Allow for both stripping at the end and mid-span
    • Designed for specific size, diameter and thickness of cables
    Stripping Tool
  • Roll-by Block
    • Swivel between messenger rollers and conductor rollers for better alignment during stringing
    • Non-slip cleat for easy attachment to the tag line
    • Individually guarded rollers to protect covered conductors
    • Available from Southwire with deposit
    Roll-by Block
  • Messenger Trolley and Tag Line
    • Designed for use with Roll-by Block to travel on messenger with pull rope
    • Counterweighted to prevent jumping off of messenger
    Messenger Trolley and Tag Line
  • Stringing Tools
    • Trains cable for ease of installation
    Stringing Tools
  • Splice Cover Kits
    • No torch required
    • Easily installed without any special tools
    • Maintains mechanical and electrical integrity of the cable
    • Compression splices not included
    Splice Cover Kits
  • Proof Positive™ Copper
    • For uninsulated hook-ups, jumpers and grounds in substations
    • Unique serial number provides proof of ownership for traceability against theft
    • Available in medium-hard-drawn or annealed tempers
    Proof Positive™ Copper
  • Bare Stranded Copper
    • For uninsulated hook-ups, jumpers and grounds in substations
    • Available in hard, medium-hard or soft (annealed) tempers
    Bare Stranded Copper
  • ACSR
    • Aluminum concentrically stranded around steel core
    • Cut to length available
    ACSR
  • AAC
    • Aluminum concentrically stranded
    • Cut to length available
    AAC
  • 1350-O Temper
    • Fully annealed aluminum rope lay stranded
    • Highly flexible
    • Cut to length available
    1350-O Temper
  • HVTC CU 3C 115TRXLPE TS PVC 5KV 133% CSA  B44

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 115TRXLPE TS PVC 5KV 133% CSA B44
  • HVTC AL 3C 90TRXLPE TS PVC 5KV 100% CSA  Y75

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 90TRXLPE TS PVC 5KV 100% CSA Y75
  • HVTC AL 3C 90EPR TS PVC 5KV 100% CSA  X77

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 90EPR TS PVC 5KV 100% CSA X77
  • HVTC AL 1C 115TRXLPE TS PVC 5KV 133% CSA  A99

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 115TRXLPE TS PVC 5KV 133% CSA A99
  • HVTC AL 1C 115EPR TS PVC 5KV 133% CSA  E58

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 115EPR TS PVC 5KV 133% CSA E58
  • HVTC AL 1C 90TRXLPE TS PVC 5KV 100% CSA Q55

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 90TRXLPE TS PVC 5KV 100% CSA Q55
  • HVTC AL 1C 90EPR TS PVC 5KV 100% CSA B82

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 90EPR TS PVC 5KV 100% CSA B82
  • HVTC AL 3C 115EPR TS PVC 5KV 133% CSA  P26

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 115EPR TS PVC 5KV 133% CSA P26
  • HVTC CU 3C 115EPR TS PVC 5KV 133% CSA W19

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 115EPR TS PVC 5KV 133% CSA W19
  • HVTC CU 3C 90EPR TS PVC 5KV 100% CSA U78

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 90EPR TS PVC 5KV 100% CSA U78
  • HVTC CU 1C 115TRXLPE TS PVC 5KV 133% CSA  X66

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 115TRXLPE TS PVC 5KV 133% CSA X66
  • HVTC CU 3C 90TRXLPE TS PVC 5KV 100% CSA  Z75

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 90TRXLPE TS PVC 5KV 100% CSA Z75
  • HVTC CU 1C 115EPR TS PVC 5KV 133% CSA  F39

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 115EPR TS PVC 5KV 133% CSA F39
  • HVTC CU 1C 90TRXLPE TS PVC 5KV 100% CSA  M45

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 90TRXLPE TS PVC 5KV 100% CSA M45
  • HVTC CU 1C 90EPR TS PVC 5KV 100% CSA  F56

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 90EPR TS PVC 5KV 100% CSA F56
  • HVTC AL 3C 115TRXLPE TS PVC 5KV 133% CSA  Z40

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 115TRXLPE TS PVC 5KV 133% CSA Z40
  • HVTC AL 3C 140EPR TS PVC 8KV 133% CSA S85

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 140EPR TS PVC 8KV 133% CSA S85
  • HVTC CU 3C 140EPR TS PVC 8KV 133% CSA W94

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 140EPR TS PVC 8KV 133% CSA W94
  • HVTC CU 3C 140TRXLPE TS PVC 8KV 133%  CSA  P31

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 140TRXLPE TS PVC 8KV 133% CSA P31
  • HVTC CU 3C 115TRXLPE TS PVC 8KV 100% CSA B03

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 115TRXLPE TS PVC 8KV 100% CSA B03
  • HVTC CU 3C 115EPR TS PVC 8KV 100% CSA  H61

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 115EPR TS PVC 8KV 100% CSA H61
  • HVTC CU 1C 140TRXLPE TS PVC 8KV 133% CSA V12

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 140TRXLPE TS PVC 8KV 133% CSA V12
  • HVTC CU 1C 140EPR TS PVC 8KV 133% CSA Q17

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 140EPR TS PVC 8KV 133% CSA Q17
  • HVTC CU 1C 115TRXLPE TS PVC 8KV 100% CSA V10

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 115TRXLPE TS PVC 8KV 100% CSA V10
  • HVTC CU 1C 115EPR TS PVC 8KV 100% CSA N37

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 115EPR TS PVC 8KV 100% CSA N37
  • HVTC AL 3C 140TRXLPE TS PVC 8KV 133% CSA M60

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 140TRXLPE TS PVC 8KV 133% CSA M60
  • HVTC AL 3C 115TRXLPE TS PVC 8KV 100% CSA  J88

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 115TRXLPE TS PVC 8KV 100% CSA J88
  • HVTC AL 3C 115EPR TS PVC 8KV 100% CSA S46

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 115EPR TS PVC 8KV 100% CSA S46
  • HVTC AL 1C 140TRXLPE TS PVC 8KV 133% CSA G80

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 140TRXLPE TS PVC 8KV 133% CSA G80
  • HVTC AL 1C 140EPR TS PVC 8KV 133% CSA D86

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 140EPR TS PVC 8KV 133% CSA D86
  • HVTC AL 1C 115TRXLPE TS PVC 8KV 100% CSA  M81

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 115TRXLPE TS PVC 8KV 100% CSA M81
  • HVTC AL 1C 115EPR TS PVC 8KV 100% CSA U38

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 115EPR TS PVC 8KV 100% CSA U38
  • HVTC CU 3C 220TRXLPE TS PVC 15KV 133% CSA U33

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 220TRXLPE TS PVC 15KV 133% CSA U33
  • HVTC CU 3C 220EPR TS PVC 15KV 133% CSA  F70

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 220EPR TS PVC 15KV 133% CSA F70
  • HVTC CU 3C 175TRXLPE TS PVC 15KV 100% CSA V96

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 175TRXLPE TS PVC 15KV 100% CSA V96
  • HVTC CU 3C 175EPR TS PVC 15KV 100% CSA C45

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 175EPR TS PVC 15KV 100% CSA C45
  • HVTC CU 1C 220TRXLPE TS PVC 15KV 133% CSA  N95

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 220TRXLPE TS PVC 15KV 133% CSA N95
  • HVTC CU 1C 220EPR TS PVC 15KV 133% CSA R77

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 220EPR TS PVC 15KV 133% CSA R77
  • HVTC CU 1C 175TRXLPE TS PVC 15KV 100% CSA M34

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 175TRXLPE TS PVC 15KV 100% CSA M34
  • HVTC CU 1C 175EPR TS PVC 15KV 100% CSA  M93

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 175EPR TS PVC 15KV 100% CSA M93
  • HVTC AL 3C 220TRXLPE TS PVC 15KV 133% CSA J40

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 220TRXLPE TS PVC 15KV 133% CSA J40
  • HVTC AL 3C 220EPR TS PVC 15KV 133% CSA Q50

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 220EPR TS PVC 15KV 133% CSA Q50
  • HVTC AL 3C 175TRXLPE TS PVC 15KV 100% CSA B95

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 175TRXLPE TS PVC 15KV 100% CSA B95
  • HVTC AL 3C 175EPR TS PVC 15KV 100% CSA Z95

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 175EPR TS PVC 15KV 100% CSA Z95
  • HVTC AL 1C 220TRXLPE TS PVC 15KV 133% CSA  X83

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 220TRXLPE TS PVC 15KV 133% CSA X83
  • HVTC AL 1C 220EPR TS PVC 15KV 133% CSA H69

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 220EPR TS PVC 15KV 133% CSA H69
  • HVTC AL 1C 175TRXLPE TS PVC 15KV 100% CSA S24

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 175TRXLPE TS PVC 15KV 100% CSA S24
  • HVTC AL 1C 175EPR TS PVC 15KV 100% CSA  P56

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 175EPR TS PVC 15KV 100% CSA P56
  • HVTC CU 3C 320TRXLPE TS PVC 25KV 133% CSA Y19

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 320TRXLPE TS PVC 25KV 133% CSA Y19
  • HVTC CU 3C 320EPR TS PVC 25KV 133% CSA U11

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 320EPR TS PVC 25KV 133% CSA U11
  • HVTC CU 3C 260TRXLPE TS PVC 25KV 100% CSA  N80

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 260TRXLPE TS PVC 25KV 100% CSA N80
  • HVTC CU 3C 260EPR TS PVC 25KV 100% CSA C06

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 260EPR TS PVC 25KV 100% CSA C06
  • HVTC CU 1C 320TRXLPE TS PVC 25KV 133% CSA C81

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 320TRXLPE TS PVC 25KV 133% CSA C81
  • HVTC CU 1C 320EPR TS PVC 25KV 133% CSA G97

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 320EPR TS PVC 25KV 133% CSA G97
  • HVTC CU 1C 260TRXLPE TS PVC 25KV 100% CSA F02

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 260TRXLPE TS PVC 25KV 100% CSA F02
  • HVTC CU 1C 260EPR TS PVC 25KV 100% CSA N03

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 260EPR TS PVC 25KV 100% CSA N03
  • HVTC AL 3C 320TRXLPE TS PVC 25KV 133% CSA L02

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 320TRXLPE TS PVC 25KV 133% CSA L02
  • HVTC AL 3C 320EPR TS PVC 25KV 133% CSA M37

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 320EPR TS PVC 25KV 133% CSA M37
  • HVTC AL 3C 260TRXLPE TS PVC 25KV 100% CSA D31

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 260TRXLPE TS PVC 25KV 100% CSA D31
  • HVTC AL 3C 260EPR TS PVC 25KV 100% CSA K40

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 260EPR TS PVC 25KV 100% CSA K40
  • HVTC AL 1C 320TRXLPE TS PVC 25KV 133% CSA E40

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 320TRXLPE TS PVC 25KV 133% CSA E40
  • HVTC AL 1C 320EPR TS PVC 25KV 133% CSA B79

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 320EPR TS PVC 25KV 133% CSA B79
  • HVTC AL 1C 260TRXLPE TS PVC 25KV 100% CSA V13

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 260TRXLPE TS PVC 25KV 100% CSA V13
  • HVTC AL 1C 260EPR TS PVC 25KV 100% CSA  J77

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 260EPR TS PVC 25KV 100% CSA J77
  • HVTC CU 1C 345EPR TS PVC 28KV 133% CSA S37

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 345EPR TS PVC 28KV 133% CSA S37
  • HVTC AL 3C 345EPR TS PVC 28KV 133% CSA D42

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 345EPR TS PVC 28KV 133% CSA D42
  • HVTC AL 3C 280TRXLPE TS PVC 28KV 100% CSA K98

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 280TRXLPE TS PVC 28KV 100% CSA K98
  • HVTC AL 1C 345EPR TS PVC 28KV 133% CSA K49

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 345EPR TS PVC 28KV 133% CSA K49
  • HVTC CU 3C 345TRXLPE TS PVC 28KV 133% CSA B29

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 345TRXLPE TS PVC 28KV 133% CSA B29
  • HVTC CU 3C 345EPR TS PVC 28KV 133% CSA T23

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 345EPR TS PVC 28KV 133% CSA T23
  • HVTC CU 3C 280TRXLPE TS PVC 28KV 100% CSA X56

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 280TRXLPE TS PVC 28KV 100% CSA X56
  • HVTC CU 3C 280EPR TS PVC 28KV 100% CSA G90

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 280EPR TS PVC 28KV 100% CSA G90
  • HVTC CU 1C 345TRXLPE TS PVC 28KV 133% CSA C93

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 345TRXLPE TS PVC 28KV 133% CSA C93
  • HVTC CU 1C 280TRXLPE TS PVC 28KV 100% CSA Z98

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 280TRXLPE TS PVC 28KV 100% CSA Z98
  • HVTC CU 1C 280EPR TS PVC 28KV 100% CSA R01

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 280EPR TS PVC 28KV 100% CSA R01
  • HVTC AL 3C 345TRXLPE TS PVC 28KV 133% CSA E94

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 345TRXLPE TS PVC 28KV 133% CSA E94
  • HVTC AL 3C 280EPR TS PVC 28KV 100% CSA X64

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 280EPR TS PVC 28KV 100% CSA X64
  • HVTC AL 1C 345TRXLPE TS PVC 28KV 133% CSA V05

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 345TRXLPE TS PVC 28KV 133% CSA V05
  • HVTC AL 1C 280TRXLPE TS PVC 28KV 100% CSA V34

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 280TRXLPE TS PVC 28KV 100% CSA V34
  • HVTC AL 1C 280EPR TS PVC 28KV 100% CSA U49

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 280EPR TS PVC 28KV 100% CSA U49
  • HVTC AL 1C 420EPR TS PVC 35KV 133% CSA C58

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 420EPR TS PVC 35KV 133% CSA C58
  • HVTC AL 1C 345TRXLPE TS PVC 35KV 100% CSA B56

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 345TRXLPE TS PVC 35KV 100% CSA B56
  • HVTC CU 3C 420TRXLPE TS PVC 35KV 133% CSA  D67

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 420TRXLPE TS PVC 35KV 133% CSA D67
  • HVTC CU 3C 420EPR TS PVC 35KV 133% CSA P51

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 420EPR TS PVC 35KV 133% CSA P51
  • HVTC CU 3C 345TRXLPE TS PVC 35KV 100% CSA R64

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 345TRXLPE TS PVC 35KV 100% CSA R64
  • HVTC CU 3C 345EPR TS PVC 35KV 100% CSA  A40

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 345EPR TS PVC 35KV 100% CSA A40
  • HVTC CU 1C 420TRXLPE TS PVC 35KV 133% CSA N55

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 420TRXLPE TS PVC 35KV 133% CSA N55
  • HVTC CU 1C 420EPR TS PVC 35KV 133% CSA D19

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 420EPR TS PVC 35KV 133% CSA D19
  • HVTC CU 1C 345TRXLPE TS PVC 35KV 100% CSA  K51

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 345TRXLPE TS PVC 35KV 100% CSA K51
  • HVTC CU 1C 345EPR TS PVC 35KV 100% CSA B55

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 345EPR TS PVC 35KV 100% CSA B55
  • HVTC AL 3C 420TRXLPE TS PVC 35KV 133% CSA Q70

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 420TRXLPE TS PVC 35KV 133% CSA Q70
  • HVTC AL 3C 420EPR TS PVC 35KV 133% CSA Q98

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 420EPR TS PVC 35KV 133% CSA Q98
  • HVTC AL 3C 345TRXLPE TS PVC 35KV 100% CSA G11

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 345TRXLPE TS PVC 35KV 100% CSA G11
  • HVTC AL 3C 345EPR TS PVC 35KV 100% CSA E44

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 345EPR TS PVC 35KV 100% CSA E44
  • HVTC AL 1C 420TRXLPE TS PVC 35KV 133% CSA  A74

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 420TRXLPE TS PVC 35KV 133% CSA A74
  • HVTC AL 1C 345EPR TS PVC 35KV 100% CSA L60

    CSA Approvals

    • TC-ER – Tray Cable – Exposed Run rating
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 345EPR TS PVC 35KV 100% CSA L60
  • HVTECK AL 3C 90TRXLPE TS PVC AIA PVC 5KV 100% CSA C95

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 90TRXLPE TS PVC AIA PVC 5KV 100% CSA C95
  • HVTECK CU 3C 115TRXLPE TS PVC AIA PVC 5KV 133% CSA G47

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 115TRXLPE TS PVC AIA PVC 5KV 133% CSA G47
  • HVTECK CU 3C 115EPR TS PVC AIA PVC 5KV 133% CSA X68

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 115EPR TS PVC AIA PVC 5KV 133% CSA X68
  • HVTECK CU 3C 90TRXLPE TS PVC AIA PVC 5KV 100% CSA M43

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 90TRXLPE TS PVC AIA PVC 5KV 100% CSA M43
  • HVTECK CU 3C 90EPR TS PVC AIA PVC 5KV 100% CSA F44

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 90EPR TS PVC AIA PVC 5KV 100% CSA F44
  • HVTECK CU 1C 115TRXLPE TS PVC AIA PVC 5KV 133% CSA  P32

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 115TRXLPE TS PVC AIA PVC 5KV 133% CSA P32
  • HVTECK CU 1C 115EPR TS PVC AIA PVC 5KV 133% CSA  N67

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 115EPR TS PVC AIA PVC 5KV 133% CSA N67
  • HVTECK CU 1C 90TRXLPE TS PVC AIA PVC 5KV 100% CSA V88

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 90TRXLPE TS PVC AIA PVC 5KV 100% CSA V88
  • HVTECK CU 1C 90EPR TS PVC AIA PVC 5KV 100% CSA S21

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 90EPR TS PVC AIA PVC 5KV 100% CSA S21
  • HVTECK AL 3C 115TRXLPE TS PVC AIA PVC 5KV 133% CSA Z67

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 115TRXLPE TS PVC AIA PVC 5KV 133% CSA Z67
  • HVTECK AL 3C 115EPR TS PVC AIA PVC 5KV 133% CSA L52

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 115EPR TS PVC AIA PVC 5KV 133% CSA L52
  • HVTECK AL 3C 90EPR TS PVC AIA PVC 5KV 100% CSA  B76

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 90EPR TS PVC AIA PVC 5KV 100% CSA B76
  • HVTECK AL 1C 115TRXLPE TS PVC AIA PVC 5KV 133% CSA  D88

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 115TRXLPE TS PVC AIA PVC 5KV 133% CSA D88
  • HVTECK AL 1C 115EPR TS PVC AIA PVC 5KV 133% CSA  A21

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 115EPR TS PVC AIA PVC 5KV 133% CSA A21
  • HVTECK AL 1C 90TRXLPE TS PVC AIA PVC 5KV 100% CSA  K01

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 90TRXLPE TS PVC AIA PVC 5KV 100% CSA K01
  • HVTECK AL 1C 90EPR TS PVC AIA PVC 5KV 100% CSA V54

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 90EPR TS PVC AIA PVC 5KV 100% CSA V54
  • HVTECK CU 3C 140TRXLPE TS PVC AIA PVC 8KV 133% CSA  J53

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 140TRXLPE TS PVC AIA PVC 8KV 133% CSA J53
  • HVTECK CU 3C 140EPR TS PVC AIA PVC 8KV 133% CSA  H23

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 140EPR TS PVC AIA PVC 8KV 133% CSA H23
  • HVTECK CU 3C 115TRXLPE TS PVC AIA PVC 8KV 100% CSA  H83

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 115TRXLPE TS PVC AIA PVC 8KV 100% CSA H83
  • HVTECK CU 3C 115EPR TS PVC AIA PVC 8KV 100% CSA G87

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 115EPR TS PVC AIA PVC 8KV 100% CSA G87
  • HVTECK CU 1C 140TRXLPE TS PVC AIA PVC 8KV 133% CSA H76

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 140TRXLPE TS PVC AIA PVC 8KV 133% CSA H76
  • HVTECK CU 1C 140EPR TS PVC AIA PVC 8KV 133% CSA  A48

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 140EPR TS PVC AIA PVC 8KV 133% CSA A48
  • HVTECK CU 1C 115TRXLPE TS PVC AIA PVC 8KV 100% CSA  U37

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 115TRXLPE TS PVC AIA PVC 8KV 100% CSA U37
  • HVTECK CU 1C 115EPR TS PVC AIA PVC 8KV 100% CSA  F98

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 115EPR TS PVC AIA PVC 8KV 100% CSA F98
  • HVTECK AL 3C 140TRXLPE TS PVC AIA PVC 8KV 133% CSA  B83

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 140TRXLPE TS PVC AIA PVC 8KV 133% CSA B83
  • HVTECK AL 3C 140EPR TS PVC AIA PVC 8KV 133% CSA  X63

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 140EPR TS PVC AIA PVC 8KV 133% CSA X63
  • HVTECK AL 3C 115TRXLPE TS PVC AIA PVC 8KV 100% CSA  F63

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 115TRXLPE TS PVC AIA PVC 8KV 100% CSA F63
  • HVTECK AL 3C 115EPR TS PVC AIA PVC 8KV 100% CSA  K46

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 115EPR TS PVC AIA PVC 8KV 100% CSA K46
  • HVTECK AL 1C 140TRXLPE TS PVC AIA PVC 8KV 133% CSA  P57

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 140TRXLPE TS PVC AIA PVC 8KV 133% CSA P57
  • HVTECK AL 1C 140EPR TS PVC AIA PVC 8KV 133% CSA  Y36

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 140EPR TS PVC AIA PVC 8KV 133% CSA Y36
  • HVTECK AL 1C 115TRXLPE TS PVC AIA PVC 8KV 100% CSA  S97

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 115TRXLPE TS PVC AIA PVC 8KV 100% CSA S97
  • HVTECK AL 1C 115EPR TS PVC AIA PVC 8KV 100% CSA V98

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 115EPR TS PVC AIA PVC 8KV 100% CSA V98
  • HVTECK CU 3C 220TRXLPE TS PVC AIA PVC 15KV 133% CSA  P91

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 220TRXLPE TS PVC AIA PVC 15KV 133% CSA P91
  • HVTECK CU 3C 220EPR TS PVC AIA PVC 15KV 133% CSA  Z72

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 220EPR TS PVC AIA PVC 15KV 133% CSA Z72
  • HVTECK CU 3C 175TRXLPE TS PVC AIA PVC 15KV 100% CSA  E35

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 175TRXLPE TS PVC AIA PVC 15KV 100% CSA E35
  • HVTECK CU 3C 175EPR TS PVC AIA PVC 15KV 100% CSA  K03

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 175EPR TS PVC AIA PVC 15KV 100% CSA K03
  • HVTECK CU 1C 220TRXLPE TS PVC AIA PVC 15KV 133% CSA Y63

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 220TRXLPE TS PVC AIA PVC 15KV 133% CSA Y63
  • HVTECK CU 1C 220EPR TS PVC AIA PVC 15KV 133% CSA  H73

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 220EPR TS PVC AIA PVC 15KV 133% CSA H73
  • HVTECK CU 1C 175TRXLPE TS PVC AIA PVC 15KV 100% CSA  C64

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 175TRXLPE TS PVC AIA PVC 15KV 100% CSA C64
  • HVTECK CU 1C 175EPR TS PVC AIA PVC 15KV 100% CSA  Q44

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 175EPR TS PVC AIA PVC 15KV 100% CSA Q44
  • HVTECK AL 3C 220TRXLPE TS PVC AIA PVC 15KV 133% CSA W72

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 220TRXLPE TS PVC AIA PVC 15KV 133% CSA W72
  • HVTECK AL 3C 220EPR TS PVC AIA PVC 15KV 133% CSA  G83

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 220EPR TS PVC AIA PVC 15KV 133% CSA G83
  • HVTECK AL 3C 175TRXLPE TS PVC AIA PVC 15KV 100% CSA  Q25

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 175TRXLPE TS PVC AIA PVC 15KV 100% CSA Q25
  • HVTECK AL 3C 175EPR TS PVC AIA PVC 15KV 100% CSA E85

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 175EPR TS PVC AIA PVC 15KV 100% CSA E85
  • HVTECK AL 1C 220TRXLPE TS PVC AIA PVC 15KV 133% CSA  L58

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 220TRXLPE TS PVC AIA PVC 15KV 133% CSA L58
  • HVTECK AL 1C 220EPR TS PVC AIA PVC 15KV 133% CSA  K06

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 220EPR TS PVC AIA PVC 15KV 133% CSA K06
  • HVTECK AL 1C 175TRXLPE TS PVC AIA PVC 15KV 100% CSA  S63

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 175TRXLPE TS PVC AIA PVC 15KV 100% CSA S63
  • HVTECK AL 1C 175EPR TS PVC AIA PVC 15KV 100% CSA U83

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 175EPR TS PVC AIA PVC 15KV 100% CSA U83
  • HVTECK CU 3C 320TRXLPE TS PVC AIA PVC 25KV 133% CSA  D98

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 320TRXLPE TS PVC AIA PVC 25KV 133% CSA D98
  • HVTECK CU 3C 320EPR TS PVC AIA PVC 25KV 133% CSA  W24

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 320EPR TS PVC AIA PVC 25KV 133% CSA W24
  • HVTECK CU 3C 260TRXLPE TS PVC AIA PVC 25KV 100% CSA  K91

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 260TRXLPE TS PVC AIA PVC 25KV 100% CSA K91
  • HVTECK CU 3C 260EPR TS PVC AIA PVC 25KV 100% CSA  J78

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 260EPR TS PVC AIA PVC 25KV 100% CSA J78
  • HVTECK CU 1C 320TRXLPE TS PVC AIA PVC 25KV 133% CSA T43

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 320TRXLPE TS PVC AIA PVC 25KV 133% CSA T43
  • HVTECK CU 1C 320EPR TS PVC AIA PVC 25KV 133% CSA  L33

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 320EPR TS PVC AIA PVC 25KV 133% CSA L33
  • HVTECK CU 1C 260TRXLPE TS PVC AIA PVC 25KV 100% CSA  L98

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 260TRXLPE TS PVC AIA PVC 25KV 100% CSA L98
  • HVTECK CU 1C 260EPR TS PVC AIA PVC 25KV 100% CSA  U35

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 260EPR TS PVC AIA PVC 25KV 100% CSA U35
  • HVTECK AL 3C 320TRXLPE TS PVC AIA PVC 25KV 133% CSA  B87

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 320TRXLPE TS PVC AIA PVC 25KV 133% CSA B87
  • HVTECK AL 3C 320EPR TS PVC AIA PVC 25KV 133% CSA  B26

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 320EPR TS PVC AIA PVC 25KV 133% CSA B26
  • HVTECK AL 3C 260TRXLPE TS PVC AIA PVC 25KV 100% CSA  Z18

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 260TRXLPE TS PVC AIA PVC 25KV 100% CSA Z18
  • HVTECK AL 3C 260EPR TS PVC AIA PVC 25KV 100% CSA  M32

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 260EPR TS PVC AIA PVC 25KV 100% CSA M32
  • HVTECK AL 1C 320TRXLPE TS PVC AIA PVC 25KV 133% CSA  M33

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 320TRXLPE TS PVC AIA PVC 25KV 133% CSA M33
  • HVTECK AL 1C 320EPR TS PVC AIA PVC 25KV 133% CSA  C87

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 320EPR TS PVC AIA PVC 25KV 133% CSA C87
  • HVTECK AL 1C 260TRXLPE TS PVC AIA PVC 25KV 100% CSA  V66

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 260TRXLPE TS PVC AIA PVC 25KV 100% CSA V66
  • HVTECK AL 1C 260EPR TS PVC AIA PVC 25KV 100% CSA  K09

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 260EPR TS PVC AIA PVC 25KV 100% CSA K09
  • HVTECK AL 1C 280EPR TS PVC AIA PVC 28KV 100% CSA  R79

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 280EPR TS PVC AIA PVC 28KV 100% CSA R79
  • HVTECK CU 3C 345TRXLPE TS PVC AIA PVC 28KV 133% CSA  X10

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 345TRXLPE TS PVC AIA PVC 28KV 133% CSA X10
  • HVTECK CU 3C 345EPR TS PVC AIA PVC 28KV 133% CSA  Q61

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 345EPR TS PVC AIA PVC 28KV 133% CSA Q61
  • HVTECK CU 3C 280TRXLPE TS PVC AIA PVC 28KV 100% CSA  F78

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 280TRXLPE TS PVC AIA PVC 28KV 100% CSA F78
  • HVTECK CU 3C 280EPR TS PVC AIA PVC 28KV 100% CSA  X73

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 280EPR TS PVC AIA PVC 28KV 100% CSA X73
  • HVTECK CU 1C 345TRXLPE TS PVC AIA PVC 28KV 133% CSA  F49

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 345TRXLPE TS PVC AIA PVC 28KV 133% CSA F49
  • HVTECK CU 1C 345EPR TS PVC AIA PVC 28KV 133% CSA  E38

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 345EPR TS PVC AIA PVC 28KV 133% CSA E38
  • HVTECK CU 1C 280TRXLPE TS PVC AIA PVC 28KV 100% CSA H59

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 280TRXLPE TS PVC AIA PVC 28KV 100% CSA H59
  • HVTECK CU 1C 280EPR TS PVC AIA PVC 28KV 100% CSA  L12

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 280EPR TS PVC AIA PVC 28KV 100% CSA L12
  • HVTECK AL 3C 345TRXLPE TS PVC AIA PVC 28KV 133% CSA  A29

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 345TRXLPE TS PVC AIA PVC 28KV 133% CSA A29
  • HVTECK AL 3C 345EPR TS PVC AIA PVC 28KV 133% CSA  P99

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 345EPR TS PVC AIA PVC 28KV 133% CSA P99
  • HVTECK AL 3C 280TRXLPE TS PVC AIA PVC 28KV 100% CSA S95

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 280TRXLPE TS PVC AIA PVC 28KV 100% CSA S95
  • HVTECK AL 3C 280EPR TS PVC AIA PVC 28KV 100% CSA  V64

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 280EPR TS PVC AIA PVC 28KV 100% CSA V64
  • HVTECK AL 1C 345TRXLPE TS PVC AIA PVC 28KV 133% CSA  M88

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 345TRXLPE TS PVC AIA PVC 28KV 133% CSA M88
  • HVTECK AL 1C 345EPR TS PVC AIA PVC 28KV 133% CSA  N70

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 345EPR TS PVC AIA PVC 28KV 133% CSA N70
  • HVTECK AL 1C 280TRXLPE TS PVC AIA PVC 28KV 100% CSA  Y66

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 280TRXLPE TS PVC AIA PVC 28KV 100% CSA Y66
  • HVTECK AL 3C 420TRXLPE TS PVC AIA PVC 35KV 133% CSA E69

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 420TRXLPE TS PVC AIA PVC 35KV 133% CSA E69
  • HVTECK CU 3C 420TRXLPE TS PVC AIA PVC 35KV 133% CSA  H77

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 420TRXLPE TS PVC AIA PVC 35KV 133% CSA H77
  • HVTECK CU 3C 420EPR TS PVC AIA PVC 35KV 133% CSA  D64

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 420EPR TS PVC AIA PVC 35KV 133% CSA D64
  • HVTECK CU 3C 345TRXLPE TS PVC AIA PVC 35KV 100% CSA B85

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 345TRXLPE TS PVC AIA PVC 35KV 100% CSA B85
  • HVTECK CU 3C 345EPR TS PVC AIA PVC 35KV 100% CSA  N83

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 345EPR TS PVC AIA PVC 35KV 100% CSA N83
  • HVTECK CU 1C 420TRXLPE TS PVC AIA PVC 35KV 133% CSA  V85

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 420TRXLPE TS PVC AIA PVC 35KV 133% CSA V85
  • HVTECK CU 1C 420EPR TS PVC AIA PVC 35KV 133% CSA  P59

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 420EPR TS PVC AIA PVC 35KV 133% CSA P59
  • HVTECK CU 1C 345TRXLPE TS PVC AIA PVC 35KV 100% CSA  X71

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 345TRXLPE TS PVC AIA PVC 35KV 100% CSA X71
  • HVTECK CU 1C 345EPR TS PVC AIA PVC 35KV 100% CSA  M94

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 345EPR TS PVC AIA PVC 35KV 100% CSA M94
  • HVTECK AL 3C 420EPR TS PVC AIA PVC 35KV 133% CSA  S45

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 420EPR TS PVC AIA PVC 35KV 133% CSA S45
  • HVTECK AL 3C 345TRXLPE TS PVC AIA PVC 35KV 100% CSA  X30

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 345TRXLPE TS PVC AIA PVC 35KV 100% CSA X30
  • HVTECK AL 3C 345EPR TS PVC AIA PVC 35KV 100% CSA Spec K38

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 345EPR TS PVC AIA PVC 35KV 100% CSA Spec K38
  • HVTECK AL 1C 420TRXLPE TS PVC AIA PVC 35KV 133% CSA  F95

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 420TRXLPE TS PVC AIA PVC 35KV 133% CSA F95
  • HVTECK AL 1C 420EPR TS PVC AIA PVC 35KV 133% CSA U79

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 420EPR TS PVC AIA PVC 35KV 133% CSA U79
  • HVTECK AL 1C 345TRXLPE TS PVC AIA PVC 35KV 100% CSA  A86

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 345TRXLPE TS PVC AIA PVC 35KV 100% CSA A86
  • HVTECK AL 1C 345EPR TS PVC AIA PVC 35KV 100% CSA Y74

    CSA Approvals

    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -40ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 345EPR TS PVC AIA PVC 35KV 100% CSA Y74
  • HVTC CU 3C 115EPR TS LSZH 5KV 133% CSA  K75

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 115EPR TS LSZH 5KV 133% CSA K75
  • HVTC CU 3C 90EPR TS LSZH 5KV 100% CSA  L04

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 90EPR TS LSZH 5KV 100% CSA L04
  • HVTC CU 1C 115EPR TS LSZH 5KV 133% CSA  L13

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 115EPR TS LSZH 5KV 133% CSA L13
  • HVTC CU 1C 90EPR TS LSZH 5KV 100% CSA  L34

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 90EPR TS LSZH 5KV 100% CSA L34
  • HVTC AL 3C 115EPR TS LSZH 5KV 133% CSA  X90

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 115EPR TS LSZH 5KV 133% CSA X90
  • HVTC AL 3C 90EPR TS LSZH 5KV 100% CSA Y51

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 90EPR TS LSZH 5KV 100% CSA Y51
  • HVTC AL 1C 115EPR TS LSZH 5KV 133% CSA  Z41

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 115EPR TS LSZH 5KV 133% CSA Z41
  • HVTC AL 1C 90EPR TS LSZH 5KV 100% CSA  Z70

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 90EPR TS LSZH 5KV 100% CSA Z70
  • HVTC AL 1C 140EPR TS LSZH 8KV 133% CSA  X51

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 140EPR TS LSZH 8KV 133% CSA X51
  • HVTC CU 3C 140EPR TS LSZH 8KV 133% CSA  J52

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 140EPR TS LSZH 8KV 133% CSA J52
  • HVTC CU 3C 115EPR TS LSZH 8KV 100% CSA  J67

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 115EPR TS LSZH 8KV 100% CSA J67
  • HVTC CU 1C 140EPR TS LSZH 8KV 133%  CSA  J71

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 140EPR TS LSZH 8KV 133% CSA J71
  • HVTC CU 1C 115EPR TS LSZH 8KV 100% CSA  K24

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 115EPR TS LSZH 8KV 100% CSA K24
  • HVTC AL 3C 140EPR TS LSZH 8KV 133% CSA W29

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 140EPR TS LSZH 8KV 133% CSA W29
  • HVTC AL 3C 115EPR TS LSZH 8KV 100% CSA  X46

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 115EPR TS LSZH 8KV 100% CSA X46
  • HVTC AL 1C 115EPR TS LSZH 8KV 100% CSA  X72

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 115EPR TS LSZH 8KV 100% CSA X72
  • HVTC CU 3C 220EPR TS LSZH 15KV 133% CSA  H70

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 220EPR TS LSZH 15KV 133% CSA H70
  • HVTC CU 3C 175EPR TS LSZH 15KV 100% CSA H97

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 175EPR TS LSZH 15KV 100% CSA H97
  • HVTC CU 1C 220EPR TS LSZH 15KV 133% CSA  I33

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 220EPR TS LSZH 15KV 133% CSA I33
  • HVTC CU 1C 175EPR TS LSZH 15KV 100% CSA  J21

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 175EPR TS LSZH 15KV 100% CSA J21
  • HVTC AL 3C 220EPR TS LSZH 15KV 133% CSA U20

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 220EPR TS LSZH 15KV 133% CSA U20
  • HVTC AL 3C 175EPR TS LSZH 15KV 100% CSA  U63

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 175EPR TS LSZH 15KV 100% CSA U63
  • HVTC AL 1C 220EPR TS LSZH 15KV 133% CSA  U64

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 220EPR TS LSZH 15KV 133% CSA U64
  • HVTC AL 1C 175EPR TS LSZH 15KV 100% CSA  V89

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 175EPR TS LSZH 15KV 100% CSA V89
  • HVTC CU 3C 320EPR TS LSZH 25KV 133% CSA  F87

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 320EPR TS LSZH 25KV 133% CSA F87
  • HVTC CU 3C 260EPR TS LSZH 25KV 100% CSA G25

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 260EPR TS LSZH 25KV 100% CSA G25
  • HVTC CU 1C 320EPR TS LSZH 25KV 133 CSA  G35

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 320EPR TS LSZH 25KV 133 CSA G35
  • HVTC CU 1C 260EPR TS LSZH 25KV 100% CSA  H01

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 260EPR TS LSZH 25KV 100% CSA H01
  • HVTC AL 3C 320EPR TS LSZH 25KV 133% CSA  Q94

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 320EPR TS LSZH 25KV 133% CSA Q94
  • HVTC AL 3C 260EPR TS LSZH 25KV 100% CSA  R46

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 260EPR TS LSZH 25KV 100% CSA R46
  • HVTC AL 1C 320EPR TS LSZH 25KV 133% CSA R91

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 320EPR TS LSZH 25KV 133% CSA R91
  • HVTC AL 1C 260EPR TS LSZH 25KV 100% CSA  S77

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 260EPR TS LSZH 25KV 100% CSA S77
  • HVTC CU 3C 345EPR TS LSZH 28KV 133% CSA  D47

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 345EPR TS LSZH 28KV 133% CSA D47
  • HVTC CU 3C 280EPR TS LSZH 28KV 100% CSA  D65

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 280EPR TS LSZH 28KV 100% CSA D65
  • HVTC CU 1C 345EPR TS LSZH 28KV 133% CSA F01

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 345EPR TS LSZH 28KV 133% CSA F01
  • HVTC CU 1C 280EPR TS LSZH 28KV 100% CSA  F58

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 280EPR TS LSZH 28KV 100% CSA F58
  • HVTC AL 3C 345EPR TS LSZH 28KV 133% CSA  N68

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 345EPR TS LSZH 28KV 133% CSA N68
  • HVTC AL 3C 280EPR TS LSZH 28KV 100% CSA  O75

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 280EPR TS LSZH 28KV 100% CSA O75
  • HVTC AL 1C 345EPR TS LSZH 28KV 133% CSA  P71

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 345EPR TS LSZH 28KV 133% CSA P71
  • HVTC AL 1C 280EPR TS LSZH 28KV 100% CSA  P98

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 280EPR TS LSZH 28KV 100% CSA P98
  • HVTC AL 1C 345EPR TS LSZH 35KV 100% CSA  N32

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 345EPR TS LSZH 35KV 100% CSA N32
  • HVTC CU 3C 420EPR TS LSZH 35KV 133% CSA  B61

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 420EPR TS LSZH 35KV 133% CSA B61
  • HVTC CU 3C 345EPR TS LSZH 35KV 100% CSA  C10

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 3C 345EPR TS LSZH 35KV 100% CSA C10
  • HVTC CU 1C 420EPR TS LSZH 35KV 133% CSA C46

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 420EPR TS LSZH 35KV 133% CSA C46
  • HVTC CU 1C 345EPR TS LSZH 35KV 100% CSA  C96

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC CU 1C 345EPR TS LSZH 35KV 100% CSA C96
  • HVTC AL 3C 420EPR TS LSZH 35KV 133% CSA  M38

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 420EPR TS LSZH 35KV 133% CSA M38
  • HVTC AL 3C 345EPR TS LSZH 35KV 100% CSA  M91

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 3C 345EPR TS LSZH 35KV 100% CSA M91
  • HVTC AL 1C 420EPR TS LSZH 35KV 133% CSA  N04

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • TC-ER – Tray Cable – Exposed Run rating TM
    • C22.2 No. 230 – Tray Cable Standard
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low temperature rating
    • +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTC AL 1C 420EPR TS LSZH 35KV 133% CSA N04
  • HVTECK CU 3C 115EPR TS LSZH AIA LSZH 5KV 133% CSA  M44

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 115EPR TS LSZH AIA LSZH 5KV 133% CSA M44
  • HVTECK CU 3C 90EPR TS LSZH AIA LSZH 5KV 100% CSA  S22

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 90EPR TS LSZH AIA LSZH 5KV 100% CSA S22
  • HVTECK CU 1C 115EPR TS LSZH AIA LSZH 5KV 133% CSA  B19

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 115EPR TS LSZH AIA LSZH 5KV 133% CSA B19
  • HVTECK CU 1C 90EPR TS LSZH AIA LSZH 5KV 100% CSA  T40

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 90EPR TS LSZH AIA LSZH 5KV 100% CSA T40
  • HVTECK AL 3C 115EPR TS LSZH AIA LSZH 5KV 133% CSA  X31

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 115EPR TS LSZH AIA LSZH 5KV 133% CSA X31
  • HVTECK AL 3C 90EPR TS LSZH AIA LSZH 5KV 100% CSA  S84

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 90EPR TS LSZH AIA LSZH 5KV 100% CSA S84
  • HVTECK AL 1C 115EPR TS LSZH AIA LSZH 5KV 133% CSA  J12

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 115EPR TS LSZH AIA LSZH 5KV 133% CSA J12
  • HVTECK AL 1C 90EPR TS LSZH AIA LSZH 5KV 100% CSA  G55

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 90EPR TS LSZH AIA LSZH 5KV 100% CSA G55
  • HVTECK AL 1C 140EPR TS LSZH AIA LSZH 8KV 133% CSA  Q28

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 140EPR TS LSZH AIA LSZH 8KV 133% CSA Q28
  • HVTECK CU 3C 140EPR TS LSZH AIA LSZH 8KV 133% CSA  D71

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 140EPR TS LSZH AIA LSZH 8KV 133% CSA D71
  • HVTECK CU 3C 115EPR TS LSZH AIA LSZH 8KV 100% CSA  O67

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 115EPR TS LSZH AIA LSZH 8KV 100% CSA O67
  • HVTECK CU 1C 140EPR TS LSZH AIA LSZH 8KV 133% CSA  K04

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 140EPR TS LSZH AIA LSZH 8KV 133% CSA K04
  • HVTECK CU 1C 115EPR TS LSZH AIA LSZH 8KV 100% CSA G03

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 115EPR TS LSZH AIA LSZH 8KV 100% CSA G03
  • HVTECK AL 3C 140EPR TS LSZH AIA LSZH 8KV 133% CSA  F79

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 140EPR TS LSZH AIA LSZH 8KV 133% CSA F79
  • HVTECK AL 3C 115EPR TS LSZH AIA LSZH 8KV 100% CSA  L06

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 115EPR TS LSZH AIA LSZH 8KV 100% CSA L06
  • HVTECK AL 1C 115EPR TS LSZH AIA LSZH 8KV 100% CSA  B15

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 115EPR TS LSZH AIA LSZH 8KV 100% CSA B15
  • HVTECK CU 3C 220EPR TS LSZH AIA LSZH 15KV 133% CSA  W13

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 220EPR TS LSZH AIA LSZH 15KV 133% CSA W13
  • HVTECK CU 3C 175EPR TS LSZH AIA LSZH 15KV 100% CSA  T21

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 175EPR TS LSZH AIA LSZH 15KV 100% CSA T21
  • HVTECK CU 1C 220EPR TS LSZH AIA LSZH 15KV 133% CSA  L39

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 220EPR TS LSZH AIA LSZH 15KV 133% CSA L39
  • HVTECK CU 1C 175EPR TS LSZH AIA LSZH 15KV 100% CSA  B62

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 175EPR TS LSZH AIA LSZH 15KV 100% CSA B62
  • HVTECK AL 3C 220EPR TS LSZH AIA LSZH 15KV 133% CSA  L61

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 220EPR TS LSZH AIA LSZH 15KV 133% CSA L61
  • HVTECK AL 3C 175EPR TS LSZH AIA LSZH 15KV 100% CSA T42

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 175EPR TS LSZH AIA LSZH 15KV 100% CSA T42
  • HVTECK AL 1C 220EPR TS LSZH AIA LSZH 15KV 133% CSA  P35

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 220EPR TS LSZH AIA LSZH 15KV 133% CSA P35
  • HVTECK AL 1C 175EPR TS LSZH AIA LSZH 15KV 100% CSA  X08

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 175EPR TS LSZH AIA LSZH 15KV 100% CSA X08
  • HVTECK CU 3C 320EPR TS LSZH AIA LSZH 25KV 133% CSA  Z39

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 320EPR TS LSZH AIA LSZH 25KV 133% CSA Z39
  • HVTECK CU 3C 260EPR TS LSZH AIA LSZH 25KV 100% CSA  T20

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 260EPR TS LSZH AIA LSZH 25KV 100% CSA T20
  • HVTECK CU 1C 320EPR TS LSZH AIA LSZH 25KV 133% CSA  V90

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 320EPR TS LSZH AIA LSZH 25KV 133% CSA V90
  • HVTECK CU 1C 260EPR TS LSZH AIA LSZH 25KV 100% CSA  Q56

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 260EPR TS LSZH AIA LSZH 25KV 100% CSA Q56
  • HVTECK AL 3C 320EPR TS LSZH AIA LSZH 25KV 133% CSA  E36

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 320EPR TS LSZH AIA LSZH 25KV 133% CSA E36
  • HVTECK AL 3C 260EPR TS LSZH AIA LSZH 25KV 100% CSA  S82

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 260EPR TS LSZH AIA LSZH 25KV 100% CSA S82
  • HVTECK AL 1C 320EPR TS LSZH AIA LSZH 25KV 133% CSA R99

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 320EPR TS LSZH AIA LSZH 25KV 133% CSA R99
  • HVTECK AL 1C 260EPR TS LSZH AIA LSZH 25KV 100% CSA  K56

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 260EPR TS LSZH AIA LSZH 25KV 100% CSA K56
  • HVTECK CU 3C 280EPR TS LSZH AIA LSZH 28KV 100% CSA  P01

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 280EPR TS LSZH AIA LSZH 28KV 100% CSA P01
  • HVTECK CU 1C 345EPR TS LSZH AIA LSZH 28KV 133% CSA F31

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 345EPR TS LSZH AIA LSZH 28KV 133% CSA F31
  • HVTECK CU 1C 280EPR TS LSZH AIA LSZH 28KV 100% CSA  L99

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 1C 280EPR TS LSZH AIA LSZH 28KV 100% CSA L99
  • HVTECK AL 3C 345EPR TS LSZH AIA LSZH 28KV 133% CSA  Z03

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 345EPR TS LSZH AIA LSZH 28KV 133% CSA Z03
  • HVTECK AL 3C 280EPR TS LSZH AIA LSZH 28KV 100% CSA W12

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 280EPR TS LSZH AIA LSZH 28KV 100% CSA W12
  • HVTECK AL 1C 345EPR TS LSZH AIA LSZH 28KV 133% CSA  I57

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 345EPR TS LSZH AIA LSZH 28KV 133% CSA I57
  • HVTECK AL 1C 280EPR TS LSZH AIA LSZH 28KV 100% CSA C38

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 280EPR TS LSZH AIA LSZH 28KV 100% CSA C38
  • HVTECK CU 3C 345EPR TS LSZH AIA LSZH 28KV 133% CSA  D43

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 345EPR TS LSZH AIA LSZH 28KV 133% CSA D43
  • HVTECK AL 3C 420EPR TS LSZH AIA LSZH 35KV 133% CSA  O43

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 3C 420EPR TS LSZH AIA LSZH 35KV 133% CSA O43
  • HVTECK AL 1C 345EPR TS LSZH AIA LSZH 35KV 100% CSA  N12

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK AL 1C 345EPR TS LSZH AIA LSZH 35KV 100% CSA N12
  • HVTECK CU 3C 420EPR TS LSZH AIA LSZH 35KV 133% CSA  R86

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments

    HVTECK CU 3C 420EPR TS LSZH AIA LSZH 35KV 133% CSA R86
  • HVTECK CU 3C 345EPR TS LSZH AIA LSZH 35KV 100% CSA B07

    CSA Approvals

    • LSZH – Low Smoke Zero Halogen (SolononTM)
    • C22.2 No. 174 - HL – All hazardous locations rating
    • Armoured Cable with inner jacket
    • C68.10 MV Shielded Power Cable Standard
    • SUN RES. - Sunlight Resistant
    • FT4 Flame Test
    • -25ºC low and +105ºC high temperature rating
    Designed for harsh Canadian environments